Specifications |
Model 2408 |
|
DC VOLTS |
Manual Ranging |
|
Ranges |
200mV, 2V, 20V, 600V |
|
Resolutions |
100 uV, 1 mV, 10 mV, 1V |
|
Basic Accuracy |
+-(1.2% rdg + 1 dgt) |
|
Overvoltage Protection |
600 V, DC + AC Peak |
|
Input Impedance |
10 MΩ |
|
AC VOLTS |
Manual ranging, average responding, rms reading |
|
Ranges |
200 mV, 2V, 20V, 600V |
|
Resolutions |
100 uV, 1 mV, 10 mV, 1V |
|
Basic Accuracy |
+-(2% rdg + 1 dgt), 50Hz - 500Hz |
|
Input Impedance |
10 MΩ |
|
DC CURRENT |
Manual ranging |
|
Ranges |
2 mA, 20 mA, 200 mA, 10A* |
|
Resolutions |
0.1 uA, 10 uA, 100 uA, 10 mA |
|
Basic Accuracy |
+-(1.5% rdg + 1 dgt), +-(3.0% rdg + 1 dgt) for 20A |
|
Overload protection |
0.8A, 250V fuse; 10A, 600V fused |
|
*10A on for 30 seconds maximum, off for 3 minutes minimum. |
|
AC CURRENT |
Manual ranging |
|
Ranges |
200 uA, 20 mA, 200 mA, 10A |
|
Resolutions |
0.1uA, 10 uA, 100 uA, 10 mA |
|
Accuracy |
+-(2.0% rdg + 4 dgt) for 10A |
|
|
+-(3.5% rdg + 4 dgt) |
|
Overload protection |
|
|
* 10A on for 30 seconds maximum, off for 3 minutes minimum. |
|
RESISTANCE |
Manual ranging |
|
Ranges |
200 Ω, 20 kOhm, 200 kOhm, 20 MOhm |
|
Resolutions |
100 mΩ, 10 Ohm, 100 Ohm, 10 kOhm |
|
Accuracy |
+-(1.5% rdg + 4 dgt), +-(3.0% rdg + 4 dgt) for 20 MΩ |
|
|
+-(5.0% rdg + 5 dgt) for 31 MΩ |
|
Open circuit voltage |
approx. 0.3VDC |
|
Overload protection |
500 VDC + AC Peak |
|
DIODE CHECK |
|
|
Resolution |
1 mV |
|
Accuracy |
+-(2.0% rdg + 1 dgt) |
|
Open Circuit Voltage |
3 VDC Typ. |
|
Test Current (approximate) |
1.0 mA |
|
Overload protection |
500 VDC + AC Peak |
|
Measures forward voltage drop of diode or semiconductor junction in mV. |
|
|
CONTINUITY CHECK |
|
Buzzer Threshold |
< 100 Ω |
|
Overload protection |
500 VDC + AC Peak |
|
Battery Test |
Does not apply |
|
Non-Contact Voltage Indicator |
Detect voltages from 70V to 480VAC |
|
|
50Hz - 60Hz |
|
Display |
2000 count, 3 1/2 digit 0.53'' LCD |
|
|
with 32 segment analog bargraph |
|
Polarity |
Automatic, (-) negative polarity indication |
|
Overrange Indication |
"OL" or "-OL" is displayed |
|
Measurement Rate |
2.5 samples per second |
|
Low Battery Indication |
Symbol Displayed |
|
Operating Temperature |
32 0 to 122 0 F (0 0 to + 50 0 C), <70% R.H. |
|
Storage Temperature |
|
|
Power |
Single standard 9V battery, NEDA 1604 or equivalent |
|
Battery Life |
200 hours typical (alkaline) |
|
Dimensions (HxWxD) |
5.63 x 2.25 x 1.375'' (143 x 68 x 47 mm) |
|
Weight |
7.27 oz. (206g). |
|
One Year Warranty |
|
Accessories |
|
SUPPLIED: Battery, Test Leads, Instruction Manual OPTIONAL: TL-2A Deluxe Test Leads, TL-3 Accessory Tip Kit (for TL-2A) TL-130A General Purpose DMM Kit Carrying Case (not included): LC-24 |