添加时间:2010-6-5 11:08:54 担当:未知 阅读:次
|
Specification | |
|
General | |
|
Detection method |
IR-absorption, dual wavelength, dual path |
|
IR-Source |
Solid state IR source, 50Hz flash |
|
Gases detected |
CO2 |
|
Self-test |
Continuous |
|
Calibration |
Factory set, no field recalibration |
|
Performance | |
|
Lifetime stability |
±5% of full scale (FS) reading |
|
Accuracy |
±3% FS between 0-50 % reading |
|
|
±5% FS between 50-80 % reading |
|
Response time |
T20 = 1 sec. |
|
|
T50 = 2.5 sec. |
|
|
T90 = 6 sec. |
|
Start-up time |
Less than 60 sec. |
|
Output signal | |
|
Standard |
Current source 4 – 20 mA, max. load impedance 500 |
|
Option |
Current sink 4 – 20 mA |
|
Option |
HART® |
|
Electrical | |
|
Power supply |
24 V DC, range18-32 V DC |
|
Power consumption |
Approx. 3.5 W |
|
Connection |
3 wires (0.5mm2 - 1.5mm2) |
|
Cable entry |
M20 EExe cable gland |
|
Temperature range | |
|
Storage |
-40°C to + 70°C |
|
Operating |
-20°C to + 45°C |
|
Humidity (operation) |
100% RH |
|
Explosion proof housing | |
|
Main compartment |
EExd IIC T6 |
|
Terminal comp. |
EExe |
|
Protection category |
IP66/IP67 DIN 40050 |
|
Housing material |
Stainless steel SIS2343 (ASTM 316) |
|
Approvals | |
|
ATEX |
Directive 94/9/EC, EMC directive 89/336/EEC Article 4 |
|
SAA (Simtars) |
AS 2380.1 / 2380.2 / 2380.6 |
|
ABS |
# 04-LD444057-PDA |
|
SIL |
Qualified for SIL2 systems |
|
Versions | |
|
Standard ranges |
10000ppm (1%), 3%, 5% 10% and 100% |
| 定货号 | 产品名称 | 规格配置 | 价格 |
|---|---|---|---|
| YD-05867-00 | 标准配置或电话咨询010-84851836 | 咨询 |