 no false alarms Mil-Ram patented Fluorine gas sensor technology  | 
| 
 Self-Calibration adjusts span monthly based on sensor life curve  | 
| 
 Auto-Gas Calibration, non-intrusive, hands-free, magnetic switches  | 
| 
 Not affected by temperature -25 deg C to +50 deg C, stable by design  | 
| 
 LCD display - 12 characters x 2 lines. Provides user interface with magnetic switches - no dip switches  | 
| 
 Offsite sensor calibration with memory chip embedded in sensor  | 
| 
 Peak value, 15-min. TWA, Remaining Sensor Life, Replace Sensor indication and number days since last gas calibration  | 
| 
 Optional Relay Module in same enclosure with low, mid, high and fault relays  | 
| 
 Can be used with Mil-Ram's Wireless Telemetry System  | 
| 
 Available suitable for use in  
SIL 2 environments  | 
| 
 Continuous advanced Diagnostics  | 
| 
 Physical Specifications   | |
| 
 Instrument Type   | 
 Detector; Monitor   | 
| 
 Mounting Type   | 
 Fixed   | 
| 
 Sensor Technology   | 
 Electrochemical   | 
| 
 Measurement Type   | |
| 
 Number of Gases Monitored   | 
 Single   | 
| 
 Measurement Type   | 
 Trace   | 
| 
 Application   | 
 Confined Space Entry; Ambient Air Monitoring; Process Gas   | 
| 
 Gas Types   | 
 Toxic; F (0.0-5.0ppm)   | 
| 
 Instrument Specifications   | |
| 
 Number Channels   | 
 1   | 
| 
 Response Time   | 
 45.00 seconds   | 
| 
 Electrical Outputs   | 
 Current   | 
| 
 Display   | 
 Analog; Digital   | 
| 
 Features   | 
 Audible or Visual Alarms; Hazardous Environment; Self Calibration   | 
| 
 Environment   | |
| 
 Operating Temperature   | 
 -13 to 122 F   | 
| 
 Operating Humidity   | 
 10 to 95 %   | 
| 产品名称 | 产品简介 | 产品编号 | 
|---|---|---|
| TA-2100-F2氟气检测仪 | Mil-Ram's New RS 485/4-20mA 3 or 4-Wire smarter Transmitter for F2 Fluorine Gas Detection. Sensor chemistry eliminates common interfering gases. | MR-09720-00 |