New universal ultrasonic flaw detector allowing to take advantage of all riches opportunities of modern digital techniques: to deduce a signal in the form A, B, C-scan, to connect the transducer on way for construction coordinate range of a product, to write down great volume of data, automatically to form reports and to print them directly from the device. Allows to measure thickness of products with high accuracy and correction of V-figurativeness, to spend manual, automated contact and immersion (special and-zone) the testing.
Allows connecting multichannel scanning systems (up to 32 channels). 
Certificated of Gosstandart of Russia RU.C.27.003. A №27905 is registered in the National register of means of measurements under №34808-07 also admitted to application in the Russian Federation.
 
| Display: color TFT 135 x 100 mm (640 х 480 pixels)  Amplifier: 0.4 - 20 МHz  TGC/DAC functions: 90 dB, 12dB/mks  Work with curve amplitude-interval: measurement in dB echelon signal relative curve and operation LED  Pulse repetition frequency: to 2000Hz  Measurement signal spectrum  | Monitor gate: three independent monitor gates with individual logic sound indication  А-, В-, С- scan  Possibility to connect the transducer of a way  Connection multichannel scanning system (to 32 channel)  Interface RS232, Ethernet  Mains power: LiOn batteries or via external plug-in power unit  7 hours battery operation  | 
 
Basic Delivery Set
UCD-60 main unit 
AC-DC power supply 220 V 
Probe cable SR50-Lemo 2 pieces 
Four transducers 
Interface cable PC 
Software support for connection PC 
Documentations 
Transport bag 
Additional implements 
Protective bag 
Batteries 
Ultrasonic transducers for different application 
Standard samples 
Scan mechanism 
Multiplexer 
Technical Characteristics
Calibration range 
min.: 0 - 2,67mks
max.: 0 - 1000mks
0,01 / 0,1/ 1/ 10/ 100mKs 
Pulse shift 
-4mks to 1000mks
0,01 / 0,1/ 1/ 10/ 100mks 
Maximal length controllable material 
6000 mm 
Sound velocity range 
1000 - 9999 m/s 
Probe delay 
0 - 100 mks
with step 0,01 / 0,1/ 1 and 10mks 
Damping 
25 ohms / 50 ohms/ 1000 ohms 
Resiver 
50 оhms/ 600 ohms 
Probe pulse 
radio-frequency pulse, amplitude 50 and 200 V. 
Damping probe pulse 
controllable up to 0 to 15 half-period 
with delay damping up to 0 to 7 half-period 
Pulse repetition frequency 
20 to 2000Hz 
1/ 5/ 10 or 100Hz 
Amplifier 
0.4-20 MHz (-6 dB) 
Gain 
100 dB, adjustable in steps 0.5, 1, 2 or 6 dB 
TGC/DAC 
70 dB, 12 dB/mкs 
Rectification 
RF (in all ranges), full-wave,
full-wave, positive and negative half wave B-scan, C-scan 
Reject 
0 - 90% screen height 
Monitor gate 
three independent monitor gates with individual logic and sound indication 
Alarm 
luminous and sonorous 
Measurement resolution 
digital display of sound path between zero and the first echo signal 
Display of amplitude 
as a percentage of the screen height,
in dB to reference test echo,
in dB reference to DAC curve. 
Display 
color, TFT 640 х 480 pixels 
130 х 100 mm 
А-signal 
480 x 300 pixels in basic mode 
Memory 
500 datasets with с А-signal
5000 checking protocol(signal, envelope, measurement result, working conditions, date, time and name protocol) 
Interface 
RS232 / Ethernet 
Dimensions transducers 
2 SP50 or Lemo0 (under order) 
Batteries 
LiOn 8 А/hr 
Operating time 
7-8 hours from batteries 
Mains power 
220 V AC 
Operating temperature 
up to -20 C to +50 C 
Dimensions (H x Wx D) 
190 mm x 285 mm x 50 mm 
Weight 
3 kg with batteries