产品描述:
				
                  Retaining the legendary CT-485 design, the CTXL Series comprises state-of-the-art circular chart recorders, available in 3 models— CTXL-TRH, CTXL-DTC, and CTXL-DPR.
The CTXL-TRH is a temperature/ relative humidity chart recorder with a temperature range of -17 to 49ºC (2 to 120ºF) and a humidity range of 2 to 98%. The CTXL-DTC is a dual thermocouple input chart recorder that accepts J, K, or T type thermocouple probes. The CTXL-DPR is a dual-process input chart recorder that accepts 0 to 1 Vdc, 0 to 5 Vdc, 0 to 10 Vdc, 0 to 20 mA, and 4 to 20 mA inputs.
All models have dual-display backlit LCDs that show 2 inputs in real time. The charted data is stored in non-volatile memory and can be downloaded to a PC for printout. Functions include audiovisual alarms with built-in relay contacts; real-time clock; monitoring of the minimum, maximum, and average values; 1-, 7-, or 32-day recording; and chart rescaling.
The high and low alarm setpoints for the 2 channels are configurable through the front-panel keypad. There are 2 built-in relays for high alarms, and 2 additional voltage outputs power external mechanical relays for low-alarm conditions.
Patented features include doublesided chart paper and the magnetic hub. And the linear pen and chart drives make it easy to understand the charts. All models come with a stabilizing arm for benchtop operation and a decorative foot cover for wall-mount applications.
For greater security, a hidden key (white box) enables/disables access to the front keypad. This will prevent unauthorized users from changing the recorder settings.
Note : Temperature/humidity sensor probe not recommended for use in corrosive environments. 
 
| CTXL Series | 
|  | Available in Computer Room White or Charcoal Gray | 
|  | Ranges of -17 to 49°C (2 to 120°F) and 2 to 98% RH (CTXL-TRH) | 
|  | Powers from 4 "D" Cell Batteries or a Universal AC Adaptor | 
|  | 203 mm (8") Chart for 1, 7, or 32-Day Recording | 
|  | Large, Bright, Dual, Backlit Display  | 
|  | Monitors Min., Max., Average Values  | 
|  | Benchtop or Wall Mount with Built-in Chart Lights | 
|  | Versatile Remote Temperature/Humidity Sensor Probe up to 12.2 m (40') | 
|  | Patented Double-Sided Chart Paper and Magnetic Hub | 
|  | 1-, 2-, 3-Year Extended Warranties Come with Extra Pens, Paper, and Batteries | 
 
				 
				
             
            
			    技术参数:
				
			      Specifications
Temperature/Relative Humidity Model CTXL-TRH
Temperature: 
Range: -17 to 49ºC (2 to 120ºF) 
Accuracy: ±1ºC (±1.8°F) 
Display Resolution: 0.1º
Relative Humidity: 
Range: 2 to 98% RH 
Accuracy: ±3% RH (@ 15 to 90% RH) 
Display Resolution: 1% RH 
Distance for Remote Probe: 12.2 m (40') maximum
Display: Custom-made, 4-digit, dual LCD with backlight 
Display Data Sampling Rate: Once per 2 seconds
Display Modes: Max, min, avg, T1 – T2
Display ºC _ _ºF Key: Switches between ºC and ºF
Display Clock: Displays the time and date for 3 seconds
Chart Speed: 1, 7, or 32 days
Chart Response Time: 0.5, 3.5, 16 min for 1, 7, and 32 days, respectively
Keypad Response: 350 ms
Chart Paper: 203 mm (8") circular, linear radial divisions, double sided
Chart Drive:
Type: Stepper motor 
Accuracy: 1% rotation 
Chart Hold-Down: Magnetic hub 
Pen Drive: 
Type: Stepper motor, linear screw drive 
Deadband: 0.5°C or °F and 3% RH 
Pen Lift: Automatic on door opening—pens are door mounted and swing clear of the chart when door opens
Configuration Modes: 
High Alarm: Channel-1 (temperature) 
Low Alarm: Channel-1 (temperature) 
High Alarm: Channel-2 (humidity) 
Low Alarm: Channel-2 (humidity) 
Clock: Time (military time) 
Clock: Date 
Clock Battery Backup: Holds clock information for 14 days when main power is removed 
Audible Alarm: Piezoelectric beeper 
Alarm Outputs: 2 separate relay contacts and 2 voltage outputs 
Relay Contacts: 2 A @ 30 Vdc (high alarm) 
Voltage Output: 100 mA to drive an external relay (low alarm) 
Alarm Deadband: 
Temperature: 0.3°C (0.5ºF) 
Humidity: 2% RH
Operating Temperature: 0 to 49°C (32 to 120ºF) 
Operating Relative Humidity: 2 to 98% RH 
Power: 4 “D” alkaline batteries and DC adaptor (included) 
Battery Life: 3 months under normal conditions 
AC Adaptor: 100 to 240 Vac input, 9 Vdc @ 1.7 A output 
Low-Battery Indicator: Icon on LCD 
Serial PC Communications: RS232, 2-way, 9600 baud 
Memory: 256K EEPROM (2.8 times worth of chart data) 
Lock/Unlock (White Box) Key: Press and hold for 3 seconds to enable/disable. When in lock mode, all keys are inactive except for the power, light, mode, clock and lock/unlock keys. 
Mounting: Keyhole slots for wall mounting; foot cover for benchtop use 
Case: Rugged ABS plastic 
Dimensions: 33.5 H x 27.1 W x 6.7 cm D (13 3/16 x 10 11/16 x 2 5/8") 
Weight: Approx 3.2 kg (7 lb) with batteries
Dual Thermocouple Input Model CTXL-DTC
Display Range:
Type K: -100 to 1000ºC (-148 to 1832ºF)
Type J: -100 to 700ºC (-148 to 1292ºF)
Type T: -100 to 300ºC (-148 to 572ºF)
Display Accuracy:
Type K: ± 2ºC ( ± 3.6°F)
Type J: ± 1.5ºC ( ± 2.7°F)
Type T: ± 1.5ºC ( ± 2.7°F)
Standard Chart Scale:
Type K: -40 to 560ºC (-40 to 1040ºF)
Type J: -40 to 260ºC (-40 to 500ºF)
Type T: -40 to 149 ºC (-40 to 300ºF)
Input Connection: Universal connector
T/C Break Indication: Display will show “Prb Err”
Out-of-Range Input: Display will flash
Display Modes: Max, min, avg, T1 – T2
 
Dual Process Input Model CTXL-DPR
Inputs: 0 to 1 V, 0 to 5 V, 0 to 10 V, 4 to 20 mA, 0 to 20 mA
Input Connection: Wire connection
Under or Over-Range Input: Display will flash 
Standard Chart Scale: 0 to 100%
				 
				  泰亚赛福作为众多知名品牌的合作伙伴,优惠的价格+完善的售后服务体系向您提供产品。font>
				泰亚赛福作为众多知名品牌的合作伙伴,优惠的价格+完善的售后服务体系向您提供产品。font>
				
             
            
			    购买流程:
				
				
				
                    ①购买产品:点击“生成订单”→填写产品数量、联系方式并提交→会员顾问订单处理→合同签订。
                    ②咨询产品:请联系会员顾问或致电会员客服电话。
                    ③如果您还不是我们的会员,请先注册。
                    ④最小起订数量:1
					
					
注意:本产品唯一个人现金委托收款人,如汇入其它个人账户本公司不承担任何责任
					
					维护担当:  
					上线时间:
					投诉电话:13801126385 13911302309 
				  
				 泰亚赛福作为众多知名品牌的合作伙伴,优惠的价格+完善的售后服务体系向您提供产品。font>
				泰亚赛福作为众多知名品牌的合作伙伴,优惠的价格+完善的售后服务体系向您提供产品。font>